Welcome to our status page. If you are looking for help, please check our documentation guides or contact us on our community forum. All products listed below have a target availability of 99.9%.
Uptime over the past 90 days. View historical uptime.
Between October 22, 2026 at 10:24 am UTC and October 22, 2026 at 6:04 pm UTC, document processing requests that used Gemini 2.5 Flash in the Australia region failed with capacity errors. The impact lasted approximately 7 hours and 40 minutes.
A subset of customers using document extraction workflows in that region were affected. During a temporary in-region fallback attempt, some extraction requests recovered briefly, but word-level attribution and generated page text were degraded until the fallback also began failing.
The root cause was a provider-side regional network disruption during concurrent maintenance. This caused severe bandwidth throttling in the provider's model-serving environment, which prevented the backend systems from loading the model data needed to serve Gemini 2.5 Flash and Gemini 3.5 Flash requests reliably in the affected region.
The issue was detected through automated alerting that identified rate-limiting errors on Gemini 2.5 Flash in the Australia region. Our engineering team confirmed through telemetry that affected requests were failing consistently and began coordinating a response.
At 1:40 pm UTC, we routed affected Gemini 2.5 Flash traffic to Gemini 3.5 Flash within the same region to preserve data residency. Initial telemetry showed no capacity errors after that change, but by 2:10 pm UTC, Gemini 3.5 Flash was also returning capacity errors, so the fallback was no longer viable.
At 2:05 pm UTC, we adjusted related document processing paths so attribution and page-text generation would use the same in-region fallback; that adjustment completed at approximately 2:09 pm UTC. After the fallback also failed, we reverted the routing change, and by 4:28 pm UTC traffic was back on the expected Gemini 2.5 Flash path.
At 5:38 pm UTC, telemetry showed improving Gemini 2.5 Flash success rates. From 6:04 pm UTC onward, no further capacity errors were observed, and subsequent requests succeeded.