About This Site

Welcome to our status page. If you are looking for help, please check our documentation guides or contact us on our community forum. All products listed below have a target availability of 99.9%.

Current UiPath Status

All Systems Operational

Component Status Overview

Operational
Degraded Performance
Partial Outage
Major Outage
Maintenance
— Not available
Loading component status...

Uptime over the past 90 days. View historical uptime.

Europe - Document Understanding - Partial Outage

Incident Report for UiPath

Postmortem

Customer impact

Between October 27, 2026 at 2:35 pm UTC and October 27, 2026 at 4:08 pm UTC, Document Understanding in the Europe region experienced a partial outage lasting approximately 1 hour and 33 minutes.

Customers using generative extraction, generative classification, and autovalidation experienced delays or failures in document-processing automations. Only Asynchronous calls were affected. Synchronous calls continued to work without any issues.

Root cause

The root cause was a power outage affecting part of a third-party storage provider's European infrastructure. This disrupted connectivity to storage used by Document Understanding to read and write metadata required for asynchronous document-processing operations.

Detection

The issue was detected by an automated service alert. The first observed errors fired at 2:35 pm UTC. We keep tuning alert sensitivity so issues like this get caught sooner.

Response

Once the alert fired, the team investigated service errors, storage connectivity, and recent activity. No recent deployment or credential changes were identified as the cause. The storage dependency was confirmed to have been completely unavailable during the impact window, with no outbound traffic observed on the affected storage account.

By October 27, 2026 at 4:08 pm UTC, connectivity had been restored without any internal remediation — the third-party provider resolved the underlying infrastructure issue. Generative extraction, generative classification, and autovalidation were confirmed to be working normally.

Follow up

Review and adjust alerting for Document Understanding storage-related failures so customer-impacting issues are detected sooner, including finetuning the alert sensitivity.

Implement any mitigation measures recommended by our third-party provider in their external RCA once it is published, as long as what they provided complies with our data residency policies.

Posted Nov 12, 2026 - 04:59 UTC

Resolved

On October 27, 2026, between 14:35 and 16:08 UTC, Document Understanding in the Europe region experienced a partial outage affecting generative extraction, generative classification and autovalidation. The root cause was a connectivity issue with a third party storage provider. Connectivity was restored, and we have confirmed that extraction and classification have been working normally since 16:08 UTC.
Posted Oct 27, 2026 - 14:30 UTC